Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Am J Trop Med Hyg ; 109(5): 1095-1106, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37722663

RESUMO

Surveillance of antimicrobial resistance among gram-negative bacteria (GNB) is of critical importance, but data for Peru are not available. To fill this gap, a non-interventional hospital-based surveillance study was conducted in 15 hospitals across Peru from July 2017 to October 2019. Consecutive unique blood culture isolates of key GNB (Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter spp.) recovered from hospitalized patients were collected for centralized antimicrobial susceptibility testing, along with linked epidemiological and clinical data. A total of 449 isolates were included in the analysis. Resistance to third-generation cephalosporins (3GCs) was present in 266 (59.2%) GNB isolates. Among E. coli (n = 199), 68.3% showed 3GC resistance (i.e., above the median ratio for low- and middle-income countries in 2020 for this sustainable development goal indicator). Carbapenem resistance was present in 74 (16.5%) GNB isolates, with wide variation among species (0% in E. coli, 11.0% in K. pneumoniae, 37.0% in P. aeruginosa, and 60.8% in Acinetobacter spp. isolates). Co-resistance to carbapenems and colistin was found in seven (1.6%) GNB isolates. Empiric treatment covered the causative GNB in 63.3% of 215 cases. The in-hospital case fatality ratio was 33.3% (92/276). Pseudomonas aeruginosa species and carbapenem resistance were associated with higher risk of in-hospital death. In conclusion, an important proportion of bloodstream infections in Peru are caused by highly resistant GNB and are associated with high in-hospital mortality.


Assuntos
Infecções por Bactérias Gram-Negativas , Sepse , Humanos , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Escherichia coli , Prevalência , Peru/epidemiologia , Mortalidade Hospitalar , Farmacorresistência Bacteriana , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Bactérias Gram-Negativas/microbiologia , Carbapenêmicos , Bactérias Gram-Negativas , Klebsiella pneumoniae , Pseudomonas aeruginosa , Sepse/tratamento farmacológico , Testes de Sensibilidade Microbiana
2.
Am J Trop Med Hyg ; 106(2): 432-440, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34872054

RESUMO

Correct processing of blood cultures may impact individual patient management, antibiotic stewardship, and scaling up of antimicrobial resistance surveillance. To assess the quality of blood culture processing, we conducted four assessments at 16 public hospitals across different regions of Peru. We assessed the following standardized quality indicators: 1) positivity and contamination rates, 2) compliance with recommended number of bottles/sets and volume of blood sampled, 3) blood culture utilization, and 4) possible barriers for compliance with recommendations. Suboptimal performance was found, with a median contamination rate of 4.2% (range 0-15.1%), with only one third of the participating hospitals meeting the target value of < 3%; and a median positivity rate of 4.9% (range 1-8.1%), with only 6 out of the 15 surveilled hospitals meeting the target of 6-12%. None of the assessed hospitals met both targets. The median frequency of solitary blood cultures was 71.9% and only 8.9% (N = 59) of the surveyed adult bottles met the target blood volume of 8 - 12 mL, whereas 90.5% (N = 602) were underfilled. A high frequency of missed opportunities for ordering blood cultures was found (69.9%, 221/316) among patients with clinical indications for blood culture sampling. This multicenter study demonstrates important shortcomings in the quality of blood culture processing in public hospitals of Peru. It provides a national benchmark of blood culture utilization and quality indicators that can be used to monitor future quality improvement studies and diagnostic stewardship policies.


Assuntos
Hemocultura/normas , Hospitais Públicos/normas , Sepse/diagnóstico , Manejo de Espécimes/normas , Hemocultura/estatística & dados numéricos , Humanos , Peru , Controle de Qualidade , Sepse/sangue , Manejo de Espécimes/estatística & dados numéricos , Inquéritos e Questionários/normas
3.
Rev. peru. med. exp. salud publica ; 38(4): 493-500, oct.-dic. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1365921

RESUMO

RESUMEN Objetivo. Determinar el título de anticuerpos frente al dominio de unión al receptor (RBD) de la proteína espiga (S) en personal de salud entre la 4.ª y 12.ª semana luego de haber recibido la vacuna BBIBP-CorV (Sinopharm). Materiales y métodos. Se incluyeron 168 trabajadores de salud de dos hospitales de la región, quienes cumplían el esquema completo con vacuna de Sinopharm, y se realizó la medición de anticuerpos en suero mediante la prueba Elecsys®Anti-SARS-CoV-2. Resultados. Todos los participantes desarrollaron anticuerpos frente al dominio RBD. El valor mínimo fue de 1,78 U/mL. En 70 (41,7%) participantes se encontraron niveles iguales o por encima de 250. La media geométrica fue de 82,6 (IC 95% 67,8-100,6). Las mujeres presentaron un mayor nivel de anticuerpos. El grupo de participantes en los que se midieron anticuerpos entre las semanas 4 y 7 posvacunación mostró niveles de anticuerpos significativamente mayores que los pacientes cuyas determinaciones fueron realizadas entre las 10 y 12 semanas posvacunación. Entre los pacientes con antecedente de COVID-19, los niveles de anticuerpos se encontraron en cifras iguales o por encima de 250 U/mL en el 88% de casos, en comparación con 6% entre aquellos sin antecedente de COVID-19, (p<0,001). Conclusión. Todos los participantes inmunizados con la vacuna BBIBP-CorV presentaron positividad a anticuerpos frente al RBD de la proteína S del SARS-CoV-2. Es necesario evaluar la correlación entre la magnitud de los títulos y la protección frente a COVID-19 y el tiempo de protección conferido por la vacuna.


ABSTRACT Objective. To determine the titer of antibodies against the receptor binding domain (RBD) of the spike protein (S) in health personnel between the 4th and 12th week after receiving the BBIBP-CorV vaccine (Sinopharm). Materials and methods. We included a total of 168 healthcare workers from two hospitals in the region, who complied with the complete Sinopharm vaccine schedule; serum antibodies were measured using the Elecsys® Anti-SARS-CoV-2 test. Results. All participants developed antibodies to the RBD domain. The lowest antibody titer level was 1.78 U/mL. Levels equal to or above 250 were found in 70 (41.7%) participants. The geometric mean was 82.6 (95% CI: 67.8-100.6). Women had higher antibody levels. Participants whose antibodies were measured between 4- and 7-weeks post-vaccination showed significantly higher antibody levels than patients whose antibody levels were measured between 10- and 12-weeks post-vaccination. Among patients with a history of COVID-19, antibody levels were found to be at or above 250 U/mL in 88% of cases, compared to 6% among those without a history of COVID-19, (p<0.001). Conclusion. All participants immunized with BBIBPCorV vaccine were positive for antibodies against the SARS-CoV-2 spike protein RBD. The correlation between the titer level and protection against COVID-19, as well as the length of the protection provided by the vaccine, needs to be evaluated.


Assuntos
Paracoccidioidomicose , Pediatria , Apêndice , Apendicite , Relatos de Casos
4.
Rev Peru Med Exp Salud Publica ; 38(4): 493-500, 2021.
Artigo em Espanhol, Inglês | MEDLINE | ID: mdl-35385001

RESUMO

OBJECTIVE.: To determine the titer of antibodies against the receptor binding domain (RBD) of the spike protein (S) in health personnel between the 4th and 12th week after receiving the BBIBP-CorV vaccine (Sinopharm). MATERIALS AND METHODS.: We included a total of 168 healthcare workers from two hospitals in the region, who complied with the complete Sinopharm vaccine schedule; serum antibodies were measured using the Elecsys® Anti-SARS-CoV-2 test. RESULTS.: All participants developed antibodies to the RBD domain. The lowest antibody titer level was 1.78 U/mL. Levels equal to or above 250 were found in 70 (41.7%) participants. The geometric mean was 82.6 (95% CI: 67.8-100.6). Women had higher antibody levels. Participants whose antibodies were measured between 4- and 7-weeks post-vaccination showed significantly higher antibody levels than patients whose antibody levels were measured between 10- and 12-weeks post-vaccination. Among patients with a history of COVID-19, antibody levels were found to be at or above 250 U/mL in 88% of cases, compared to 6% among those without a history of COVID-19, (p<0.001). CONCLUSION.: All participants immunized with BBIBPCorV vaccine were positive for antibodies against the SARS-CoV-2 spike protein RBD. The correlation between the titer level and protection against COVID-19, as well as the length of the protection provided by the vaccine, needs to be evaluated.


OBJETIVO.: Determinar el título de anticuerpos frente al dominio de unión al receptor (RBD) de la proteína espiga (S) en personal de salud entre la 4.ª y 12.ª semana luego de haber recibido la vacuna BBIBP-CorV (Sinopharm). MATERIALES Y MÉTODOS.: Se incluyeron 168 trabajadores de salud de dos hospitales de la región, quienes cumplían el esquema completo con vacuna de Sinopharm, y se realizó la medición de anticuerpos en suero mediante la prueba Elecsys® Anti-SARS-CoV-2. RESULTADOS.: Todos los participantes desarrollaron anticuerpos frente al dominio RBD. El valor mínimo fue de 1,78 U/mL. En 70 (41,7%) participantes se encontraron niveles iguales o por encima de 250. La media geométrica fue de 82,6 (IC 95% 67,8-100,6). Las mujeres presentaron un mayor nivel de anticuerpos. El grupo de participantes en los que se midieron anticuerpos entre las semanas 4 y 7 posvacunación mostró niveles de anticuerpos significativamente mayores que los pacientes cuyas determinaciones fueron realizadas entre las 10 y 12 semanas posvacunación. Entre los pacientes con antecedente de COVID-19, los niveles de anticuerpos se encontraron en cifras iguales o por encima de 250 U/mL en el 88% de casos, en comparación con 6% entre aquellos sin antecedente de COVID-19, (p<0,001). CONCLUSIÓN.: Todos los participantes inmunizados con la vacuna BBIBP-CorV presentaron positividad a anticuerpos frente al RBD de la proteína S del SARS-CoV-2. Es necesario evaluar la correlación entre la magnitud de los títulos y la protección frente a COVID-19 y el tiempo de protección conferido por la vacuna.


Assuntos
Anticorpos Neutralizantes , Vacinas contra COVID-19 , COVID-19 , Anticorpos Antivirais , COVID-19/prevenção & controle , Vacinas contra COVID-19/imunologia , Feminino , Pessoal de Saúde , Humanos , Imunidade Humoral , Peru , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...